1. Does not turn on: the voltage is too low; the switch is inflexible or damaged; the power supply is missing.


2. No suction: the valve of the suction pipeline is not opened; the pump is reversed.


3. Too many large air bubbles: too much inhalation affects the effect of dissolved air; air leakage in the inlet pipeline, valve interface or drain pipeline, valve interface; problems in the release pipeline, too many elbows, and the release port is downward; the outlet pipe The distance between the pressure regulating valve of the road and the water treatment tank is too long, and there are too many elbows.


4. The effect of dissolved air is unstable: the drainage pipeline is blocked by large air bubbles. Adjust the intake air flow.